Enter the household’s use. Compare the options. Review the assumptions together.

Sample values loaded · edit for your site
Expected daily use—kWh / day
PV target with margin—kWp DC
01

Electricity use

Input method

Bill ÷ rate gives approximate kWh. Use actual billed kWh when available; fixed charges can distort a bill estimate.

₱14.50 is an editable example, not a current Cebu tariff. Check the client’s bill.

02

Expected future loads

Add only new use beyond the current bill. For aircon, use expected average electrical watts, not cooling capacity.

No additional loads included.

Additional daily energy0.00 kWh
03

Site assumptions

4 hours is a starting assumption, not measured Cebu weather data. Margin adds planning headroom to energy demand.

80% means a combined 20% allowance for heat, dirt, wiring and conversion. Adjust for the site; inverter clipping is not modeled. Battery runtime has its own efficiency assumption below.

04

Battery backup

Load used for runtime—

Daily use ÷ 24 is a rough whole-house average. Enter the actual average power of the backed-up appliances for a better estimate.

SOC means state of charge. 100% → 20% uses 80% of nominal energy. Use a reserve allowed by the battery manufacturer.

90% efficiency and 50 W idle draw are editable examples. Runtime assumes no solar or grid charging, at nominal new-battery capacity.

YOUR ENERGY ESTIMATEPreliminary
Expected daily use—kWh / day, including future loads
Calculated PV target—kWp DC, including sizing margin
Current household—
+
Future loads—
=
Planning demand—
WHOLE-PANEL STARTING POINT
——

Panel count rounds up to whole modules. Inverter choice stays separate.

See the calculation

Live math

    Compare inverter options

    All inverter rows are shown so you can find the right battery voltage. Starting panel counts sit near each inverter rating; edit them to match a real package.

    Choose the battery voltage in the first column: for compatible 1–3 kW rows, select 24 V system or 48–60 V class · 51.2 V nominal. The Battery bank dropdown will then show only matching options. 24V choices are 24V 200Ah (4.80 kWh) and 24V 315Ah (7.56 kWh); 4 kW and larger rows remain 48–60V class only.

    Inverter, solar array and battery bank comparison. Battery runtime uses the backup load and SOC assumptions. Generation is estimated before inverter clipping.
    Inverter
    kW AC · battery voltage
    Panels
    630 W each
    PV array
    kWp DC
    Daily yield
    kWh
    Vs. demand
    energy only
    Battery bank
    model-compatible voltage
    Battery runtime
    to 20% SOC
    Review
    Shaded rows meet the PV energy target including margin.

    Battery runtime calculation

    To minimum SOC

    Common battery reference · 1 × 314 Ah / 51.2 V

    Nominal bank energy—
    Energy above reserve—
    Estimated runtime—

      Cebu battery size references

      Capacity presets: 100 Ah (5.12 kWh), 200 Ah (10.24 kWh), 300 Ah (15.36 kWh), and your usual 314 Ah (16.0768 kWh), all at 51.2 V. Use 100 Ah for lighter backup needs, 200 Ah as a middle option, or 314 Ah for more energy per pack; choose quantity from the load and desired hours.

      Cebu ABC Solar Electronics in Talisay lists 100 Ah LVTOPSUN, 200 Ah and 300 Ah LVTOPSUN batteries. Listings checked 6 October 2026; confirm current stock, exact specs, warranty and inverter compatibility before quoting.

      Parallel-bank calculations keep voltage at 51.2 V and add Ah and kWh. Each bank assumes matching approved packs, not mixed sizes or brands. A preset is a capacity comparison, not certification of a battery/inverter pairing.

      Client review

      Select an option above to include it in the discussion.

      Install Solar Sizing

      On Android, open this page in Chrome. Use the browser menu and choose Install app or Add to Home screen.

      On iPhone, open in Safari, tap Share, then Add to Home Screen.

      The calculator works offline after the first successful online visit. External links need internet. Assessment inputs clear when you refresh or close the app.